Temperature control design of 2 ~ 8 ℃ cold storage for 60 m ~ 3 medical supplies

Temperature control design of 2 ~ 8 ℃ cold storage for 60 m ~ 3 medical supplies

written words: [big] [middle] [small] QR code of mobile phone page QR code Number of visits: twenty-nine

Safety is the primary characteristic of 电竞押注s. Strict standards should be used in many links of 电竞押注 production, transportation and storage to ensure the quality and safety of 电竞押注s, so as to achieve the purpose of 电竞押注 safety, reliability and effectiveness.

Let's focus on 60m3 Cold storage of medical supplies 2 ~ 8 ℃ storage temperature control instructions and inspection temperature were analyzed.

In order to continuously strengthen the 电竞押注 quality management and control, standardize the 电竞押注 maintenance behavior, and ensure the safety, effectiveness and uniformity of 电竞押注s within the validity period, it is necessary to effectively verify the 2 ~ 8 ℃ storage environment of 60 m ~ 3 medical supplies cold storage.

 

Refrigerated medicine is a kind of special medicine, which requires to be stored at low temperature, such as freeze-dried powder injection, biological products, blood products, vaccines, etc., and its unique properties determine the safety of 电竞押注 use of the common people. Therefore, the temperature verification of 2 ~ 8 ℃ in the 60 m ~ 3 medical supplies cold storage is selected as the implementation object of the verification scheme.

 

The temperature verification method of GSP / 60m 3 cold storage for medical supplies at 2 ~ 8 ℃ is divided into qualified area, inspection area and return area according to function.

In the 60 m ~ 3 cold storage for medical supplies, 15 temperature collectors are arranged according to different positions, such as air outlet, return air outlet, corner, near door, floor rack, shelf, etc., to record the 24-hour temperature change data of each point, and the data is recorded once every 5 minutes through the temperature monitoring system. During this period, simulated door opening test and normal door opening test were carried out.

 

At present, more and more attention has been paid to the influence of 电竞押注 transportation, storage, storage and maintenance on 电竞押注 quality, especially the cold storage of medical supplies. The properties of refrigerated 电竞押注s are relatively unstable and sensitive to temperature. Only when the 电竞押注s are stored in specific temperature conditions can the efficacy of 电竞押注s not be affected by temperature changes. "Cold chain does not fall off the chain", every circulation link of refrigerated 电竞押注s can not be ignored. The test results show that all facilities and equipment in the cold storage of medical supplies are in normal operation, and the temperature in the verification area can be controlled within the 电竞押注 storage conditions (usually 2 ~ 8 ℃), so as to meet the requirements of 电竞押注 cold storage.

 

The results of door opening test show that the temperature of the right area of the cold storage door of medical supplies is affected by the door opening, which is reflected in the temperature rise. The effect of short-term opening time (within 2 minutes) on the temperature of medical cold storage is limited, but it is close to the upper limit. It is suggested that the door opening time should be shortened during normal operation and should be controlled within 2 minutes.

 

More questions about the design of 2 ~ 60 ℃ cold storage are welcome!!